Product Description:
SKINTACT Easibeat Multi-function Defibrillation Electrodes are designed for the use of external defibrillation, non-invasive pacing, synchronized cardioversion and monitoring on adults and children over 8 years weighing more than 25 kg (55 lbs.). Our unique C-line technology guarantees perfect processing of all materials according ISO 13485 and at the same time reduces cost.
Excellent Skin Coupling: Proper adhesion between electrodes and skin ensures firm contact to all skin types and is gentle to the patient’s skin: Optimal water absorption of gel, good adhesion on perspiring skin, utilization of minimal thickness layers of materials increases flexibility, maximum contact area means minimum impedance values and in addition reduces thermical and mechanical exposure of the skin. Overlapping Gel: This unique technology minimizes the risk of burns because of: elimination of tin edge exposure, better current distribution, no flashover, and minimized edge effect.
Multi-function: Continuity of patient care eliminates replacing the electrodes between developing stages of the patient’s treatment. Quality Assurance: Each set is subject to 100% test and inspection before packaging. Clearly Printed Instructions: Instructions are clearly printed in two colors (green, black) on the electrodes for correct placement. Quick’n’Easy: Extended Liner designed specifically for quick and easy application and removal. See tab for more information.
- Zoll
- Connector (compatible): Zoll E Series, Zoll M Series, Zoll R Series, Zoll PD1200, Zoll PD1400, Zoll PD 1600, Zoll PD 1700, Zoll PD2000
- Packaging Standard: 1 pair/pouch, 10 pouches/box, 60 pouches/case
- Non-invasive pacing, synchronized cardioversion and monitoring on adults and children over 8 years weighing more than (55 lbs)
- Perfect processing of all materials according ISO 13485
- Shelf Life: 36 Months
- Latex Free
- Highest degree of skin contact, minimal impedance and is gentle to the patient’s skin
- Excellent Skin Coupling
- Proper adhesion between electrodes and skin ensures firm contact to all skin types including perspiring skin
- Maximum contact: minimum impedance values, reduces thermical and mechanical exposure of the skin
- Overlapping Gel: minimizes the risk of burns
- Elimination of tin edge exposure, better current distribution, no flashover, and minimized edge effect
- Multifunction: eliminates replacing the electrodes between developing stages of the patient’s treatment
- Quality Assurance: Each set is subject to 100% test and inspection before packaging
- Clearly Printed Instructions: Instructions are clearly printed in two colors (green, black) on the electrodes for correct placement
- Extended Liner for quick and easy application and removal